Mechanical Properties Tensile force 100 N
Bending radius ≥ 33 mm during operation (without load)
≥ 65 mm during installation (with load)
Temperature range During operation -55°C…+ 60°C
During installation -15°C…+ 50°C
Electrical Properties DC loop residence ≤ 17.6 Ω / 100 m
(at 20°C ± 5°C) Resistance unbalance ≤ 2 %
Test voltage DC, 1 min, core/core 1000 V
Insulation resistance 500 V ≥ 5000 MΩ * km
Capacitance 48 pF / m nom.
Capacitance unbalance ≤ 1500 pF / km
Mean characteristic
impedance 100 ± 5 Ω
Nominal velocity of
propagation Approx. 67 %
Propagation delay At 1 MHz ≤ 535 ns / 100 m
Delay skew ≤ 20 ns / 100 m
Coupling attenuation ≥ 40 dB
Balance TCL At 1 MHz ≤ 55 dB
At 10 MHz ≤ 40 dB
At 100 MHz ≤ 35 dB
Typical transmission characteristics (at 20°C)
f Attenuation NEXT PS-NEXT ACR-F 1) PS-ACR-F 1) Return loss
(MHZ) (Db/100 m) (dB) (dB) (dB/100 m) (dB/100 m) (dB)
Max Typ Min Typ Min Typ Min Typ Min Typ Min Typ
4 3.8 3.8 66 71 63 66 58 59 55 56 23 26
10 6 5.6 60 65 57 60 50 50 47 48 25 28
20 8.5 8.5 56 60 53 56 44 45 41 42 25 28
62.5 15.5 15.1 48 56 45 48 34 35 31 32 21.5 25
100 19.9 19.1 45 50 42 45 30 31 27 28 20.1 23
250 33 32 39 44 36 39 22 23 19 20 17.3 20
450 – 44.8 – 40 – 35 – 15 – 17 – 20
Cable Part Number
Part No. Item
PL-C6-LSZH-W ProLink CAT. 6 U/UTP CABLE, 4 PAIR 23 AWG , LSZH , White , RIB
PL-C6-PVC-W ProLink CAT. 6 U/UTP CABLE, 4 PAIR 23 AWG , PVC , White , RIB
ProLink CAT. 6 U/UTP CABLE, 4 PAIR 23 AWG , White , RIB PL-C6-PVC-W
Availability: 5 in stock
EGP5,200
Description
ProLink CAT6 U/UTP Cable, 23AWG, white jacket, 4 pair count, 305 m length Reel in a box
- Conductor: Solid copper wire AWG23 (Ø 0.58mm).
- Insulation: Polyethylene ≤ Ø 1.1 mm.
- Cable lay up: 4 pairs to the core, non-metallic cross separator (spline).
- Cable core lying: Waterproof compound to prevent moisture migration and water protection.
- Sheath: White, PVC.
5 in stock
Compare
-
Description
- |
-
Add Tags
- |
Tail sed sausage magna quis commodo snasae. Aliquip strip steak esse ex in ham hock fugiat in. Labore velit pork belly eiusmod ut shank doner capicola consectetur landjaeger fugiat excepteur short loin. Pork belly laboris mollit in leberkas qui. Pariatur snasae aliqua pork chop venison veniam. Venison sed cow short loin bresaola shoulder cupidatat capicola drumstick dolore magna shankle.
PROLINK Cat.6 patch cords are used for connecting the network equipment to patch panels and telecommunications outlets.
They are suitable for frequencies of up to 250 MHz
PROLINK Cat.6 patch cords are used for connecting the network equipment to patch panels and telecommunications outlets.
They are suitable for frequencies of up to 250 MHz
Description
ProLink CAT6 U/UTP Cable, 23AWG, white jacket, 4 pair count, 305 m length Reel in a box
- Conductor: Solid copper wire AWG23 (Ø 0.58mm).
- Insulation: Polyethylene ≤ Ø 1.1 mm.
- Cable lay up: 4 pairs to the core, non-metallic cross separator (spline).
- Cable core lying: Waterproof compound to prevent moisture migration and water protection.
- Sheath: Orange, PVC.
PROLINK Cat.6 patch cords are used for connecting the network equipment to patch panels and telecommunications outlets.
They are suitable for frequencies of up to 250 MHz
PROLINK Cat.6 patch cords are used for connecting the network equipment to patch panels and telecommunications outlets.
They are suitable for frequencies of up to 250 MHz
PROLINK Cat.6 patch cords are used for connecting the network equipment to patch panels and telecommunications outlets.
They are suitable for frequencies of up to 250 MHz
PROLINK Cat.6 patch cords are used for connecting the network equipment to patch panels and telecommunications outlets.
They are suitable for frequencies of up to 250 MHz
PROLINK Cat.6 patch cords are used for connecting the network equipment to patch panels and telecommunications outlets.
They are suitable for frequencies of up to 250 MHz
PROLINK Cat.6 patch cords are used for connecting the network equipment to patch panels and telecommunications outlets.
They are suitable for frequencies of up to 250 MHz
PROLINK Cat.6 patch cords are used for connecting the network equipment to patch panels and telecommunications outlets.
They are suitable for frequencies of up to 250 MHz
PROLINK Cat.6 patch cords are used for connecting the network equipment to patch panels and telecommunications outlets.
They are suitable for frequencies of up to 250 MHz